2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
DPCN
2-way, pilot operated, directional valve with drain to port 4 - normally closed
SERIES 2 / CAPACITY: 60 L/min. / CAVITY: T-22A
Normally closed, pilot-operated, 2-way directional cartridges are switching devices typically used in moderate flow
circuits. They can be used by themselves or to actuate larger pilot operated directional cartridges or logic
cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
TECHNICAL DATA
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,16 - 0,25 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 15 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-022-007
Seal kit - Cartridge Polyurethane: 990-022-002
Seal kit - Cartridge Viton: 990-022-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi
(70 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400 psi (28
bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
W 150 - 4500 psi (10,5 - 315 bar), 1000
psi (70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
snhy.com/
DPCN
TECHNICAL FEATURES
Port 4 can be blocked to prevent the valve from shifting.
Port 3 can be used as a work port.
Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
Model Code Example: DPCNLANCONFIGURATION OPTIONS
Created on 12/08/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
Pressure at port 4 is directly additive to the setting of the valve.
This valve is not bistable; it is capable of modulating between the two positions shown.
Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve
setting. If this is a problem, the direct acting version of this valve would be a solution.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.